Efficacy and safety of sensor-augmented pump therapy (SAPT) with predictive low-glucose management in patients diagnosed with type 1 diabetes mellitus previously treated with SAPT and low glucose suspend

Translated title of the contribution: Efficacy and safety of sensor-augmented pump therapy (SAPT) with predictive low-glucose management in patients diagnosed with type 1 diabetes mellitus previously treated with SAPT and low glucose suspend

Ana María Gómez, Diana Cristina Henao, Angelica Imitola, Oscar Mauricio Muñoz, Martín Alonso Rondón Sepúlveda, Laura Kattah, Juan Sebastian Guerrero, Elly Morros, Juan Pablo Llano, Maira García Jaramillo, Fabián León-Vargas

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Background: Sensor-augmented insulin pump therapy (SAPT) with low-glucose suspend (LGS) is an effective and safe alternative for treating patients with type 1 diabetes mellitus (T1DM). New predictive low-glucose management (PLGM) systems decrease the severity and duration of hypoglycemic events. However, evidence of benefits in patients previously treated with SAPT-LGS is limited. Methods: A prospective before-after study was conducted in patients with T1DM treated with SAPT-LGS, who were switched to the Minimed® 640G system with SmartGuard® to assess the impact on A1c levels, severe hypoglycemia (SH), hypoglycemia unawareness (HU), and area under the curve (AUC) <70 mg/dL after three months of follow-up. Results: Fifty-five patients with T1DM with a mean age of 37.9 (IQR 6, 79) years and a mean baseline A1c level of 7.52 ± 1.11% were enrolled. After three months under PLGM, A1c levels significantly decreased to 7.18 ± 0.91% (p = 0.004). SH rate decreased from 2.47 (CI 0.44, 4.90) to 0.87 (CI 0.22, 1.52) events/patient-year (Incidence rate ratio 0.353, 95% CI 0.178, 0.637), AUC <70 mg/dL decreased from 0.59 ± 0.76 to 0.35 ± 0.65 mg/dL x minute (p = 0.030). HU determined by Clarke questionnaire resolved in 23 out of 30 patients (p = 0.002). Conclusions: This study suggests that SAPT with PLGM decreases the frequency of SH, HU, exposure to glucose levels below 70 mg/dL, and A1c levels. Based on these results, this therapy should be considered in T1DM patients previously treated with SAPT-LGS with persistent SH and HU. Further clinical trials comparing the efficacy and safety of these features are required.

Translated title of the contributionEfficacy and safety of sensor-augmented pump therapy (SAPT) with predictive low-glucose management in patients diagnosed with type 1 diabetes mellitus previously treated with SAPT and low glucose suspend
Original languageEnglish
Pages (from-to)451-457
Number of pages7
JournalEndocrinologia, Diabetes y Nutricion
Volume65
Issue number8
DOIs
StatePublished - Oct 2018
Externally publishedYes

Keywords

  • Continuous glucose monitoring
  • Low glucose suspend
  • Predictive low-glucose suspend
  • Sensor-augmented pump therapy
  • Severe hypoglycemia
  • Type 1 diabetes mellitus

Fingerprint

Dive into the research topics of 'Efficacy and safety of sensor-augmented pump therapy (SAPT) with predictive low-glucose management in patients diagnosed with type 1 diabetes mellitus previously treated with SAPT and low glucose suspend'. Together they form a unique fingerprint.

Cite this