T1 - Evaluación preliminar de la prueba comercial Chagas (Trypanosoma cruzi) IgG-ELISA® en individuos colombianos
AU - Llano, Mónica
AU - Pavía, Paula
AU - Flórez, Astrid Carolina
AU - Cuéllar, Adriana
AU - González, John M.
AU - Puerta, Concepción
PY - 2014
Y1 - 2014
N2 - Introduction: The diagnosis of Chagas' disease is essential to provide early treatment and improve patients' prognosis. The discriminatory efficiency of the serological tests varies according to the disease prevalence and the test-antigen used. Objective: To evaluate the discriminatory efficiency of the commercial kit Chagas (Trypanosoma cruzi) IgG-ELISA® (Nova Tec Immunodiagnostica GmbBH) in a group of Colombian individuals, using indirect immunofluorescence antibody testing (IFAT) and enzyme immunoassay (ELISA) tests as references. Materials and methods: Seventy-eight samples from chronic chagasic patients (36 asymptomatic and 42 symptomatic) and 21 healthy controls were included. Seventeen samples from non-infected people with Chagas' disease epidemiological risk, seven with leishmaniasis and nine with non-chagasic cardiomyopathy were also analyzed. Real time PCR was performed on four individuals whose results differed among tests. Results: Significant differences at 450 nm optical absorbance were found (p<0.0001) when the median absorbance values of healthy controls (0.143), asymptomatic (2.401) and symptomatic (2.776) chagasic patients were compared, as well as when asymptomatic and symptomatic patients (p=0.0408) and seronegative people with epidemiological risk (0.232), cardiomyopathy (0.367) or leishmaniasis (0.337) were compared with chagasic patients (p<0.0001). Finally, there were differences among healthy controls and non-infected people with epidemiological risk (p=0.0264), patients with non-chagasic cardiomyopathy (p=0.0015) and patients with leishmaniasis (p=0.002). Real-time PCR was positive in three out of four analyzed cases. Conclusions: The commercial ELISA test allowed us to discriminate the chagasic patients from the controls. A phase II study of diagnostic tests for determining field reliability of this test is required.
AB - Introduction: The diagnosis of Chagas' disease is essential to provide early treatment and improve patients' prognosis. The discriminatory efficiency of the serological tests varies according to the disease prevalence and the test-antigen used. Objective: To evaluate the discriminatory efficiency of the commercial kit Chagas (Trypanosoma cruzi) IgG-ELISA® (Nova Tec Immunodiagnostica GmbBH) in a group of Colombian individuals, using indirect immunofluorescence antibody testing (IFAT) and enzyme immunoassay (ELISA) tests as references. Materials and methods: Seventy-eight samples from chronic chagasic patients (36 asymptomatic and 42 symptomatic) and 21 healthy controls were included. Seventeen samples from non-infected people with Chagas' disease epidemiological risk, seven with leishmaniasis and nine with non-chagasic cardiomyopathy were also analyzed. Real time PCR was performed on four individuals whose results differed among tests. Results: Significant differences at 450 nm optical absorbance were found (p<0.0001) when the median absorbance values of healthy controls (0.143), asymptomatic (2.401) and symptomatic (2.776) chagasic patients were compared, as well as when asymptomatic and symptomatic patients (p=0.0408) and seronegative people with epidemiological risk (0.232), cardiomyopathy (0.367) or leishmaniasis (0.337) were compared with chagasic patients (p<0.0001). Finally, there were differences among healthy controls and non-infected people with epidemiological risk (p=0.0264), patients with non-chagasic cardiomyopathy (p=0.0015) and patients with leishmaniasis (p=0.002). Real-time PCR was positive in three out of four analyzed cases. Conclusions: The commercial ELISA test allowed us to discriminate the chagasic patients from the controls. A phase II study of diagnostic tests for determining field reliability of this test is required.
KW - Antibodies
KW - Chagas disease/diagnosis
KW - Enzyme-linked immunosorbent assay
KW - Polymerase chain reaction
KW - Trypanosoma cruzi
UR - http://www.scopus.com/inward/record.url?scp=84904398871&partnerID=8YFLogxK
U2 - 10.7705/biomedica.v34i2.1580
DO - 10.7705/biomedica.v34i2.1580
M3 - Artículo
AN - SCOPUS:84904398871
SN - 0120-4157
VL - 34
SP - 228
EP - 236
JO - Biomedica
JF - Biomedica
IS - 2
ER -