N2 - Objective: The aim of this study was to analyze whether higher transcatheter aortic valve implantation with self-expandable valves using the right and left cusp overlap strategy decreases the need for permanent pacemaker. Methods: A total of 164 consecutive patients undergoing TAVI with self-expandable valves were analyzed: 101 (61.6%) im-planted with the conventional technique (CON) using the three-cusp coplanar view, and 63 (38.4%) using the right and left cusp overlap (COVL) technique. The primary endpoint (PEP) was the need for permanent pacemaker (PPM) at 30 days. Results: Mean age, prevalence of male gender, hypertension, prior coronary artery bypass graft surgery (CABG), and history of stroke, kidney function or hemodialysis was not different between groups. Patients in the COVL group had more diabetes, coronary percutaneous transluminal coronary angioplasty (PTCA) and prior infarct, and pre-TAVI PTCA was similar, with higher STS score (6.3±2.2 vs. 5.8±2.4; p=0.05). The presence of atrial fibrillation was greater in the COVL group, without differences in right or left bundle branch or atrioventricular block. There was no difference in aortic valve area, mean gradient and left ventricular ejection fraction. At 30 days, the need of PPM was significantly reduced with the COVL technique (6.3%% vs. 17.8%; p=0.03). No difference was observed in mortality, stroke, major bleeding, acute myocardial infarction or aortic regurgitation, and the presence of new-onset complete left bundle branch block was lower in the COVL group (4.8% vs. 12.9%; p=0.08). Conclusions: Use of the COVL technique, which allows higher self-expandable valve implantation during TAVI, was feasible and safe, decreasing the need for PPM without increasing complications.
AB - Objective: The aim of this study was to analyze whether higher transcatheter aortic valve implantation with self-expandable valves using the right and left cusp overlap strategy decreases the need for permanent pacemaker. Methods: A total of 164 consecutive patients undergoing TAVI with self-expandable valves were analyzed: 101 (61.6%) im-planted with the conventional technique (CON) using the three-cusp coplanar view, and 63 (38.4%) using the right and left cusp overlap (COVL) technique. The primary endpoint (PEP) was the need for permanent pacemaker (PPM) at 30 days. Results: Mean age, prevalence of male gender, hypertension, prior coronary artery bypass graft surgery (CABG), and history of stroke, kidney function or hemodialysis was not different between groups. Patients in the COVL group had more diabetes, coronary percutaneous transluminal coronary angioplasty (PTCA) and prior infarct, and pre-TAVI PTCA was similar, with higher STS score (6.3±2.2 vs. 5.8±2.4; p=0.05). The presence of atrial fibrillation was greater in the COVL group, without differences in right or left bundle branch or atrioventricular block. There was no difference in aortic valve area, mean gradient and left ventricular ejection fraction. At 30 days, the need of PPM was significantly reduced with the COVL technique (6.3%% vs. 17.8%; p=0.03). No difference was observed in mortality, stroke, major bleeding, acute myocardial infarction or aortic regurgitation, and the presence of new-onset complete left bundle branch block was lower in the COVL group (4.8% vs. 12.9%; p=0.08). Conclusions: Use of the COVL technique, which allows higher self-expandable valve implantation during TAVI, was feasible and safe, decreasing the need for PPM without increasing complications.
KW - Aortic Valve Insufficiency
KW - Follow
KW - Self Expandable Metallic Stents
KW - Transcatheter Aortic Valve Replacement
KW - Up Studies
UR - http://www.scopus.com/inward/record.url?scp=85134370203&partnerID=8YFLogxK
U2 - 10.7775/rac.es.v90.i2.20481
DO - 10.7775/rac.es.v90.i2.20481
M3 - Artículo
AN - SCOPUS:85134370203
SN - 0034-7000
VL - 90
SP - 112
EP - 119
JO - Revista Argentina de Cardiologia
JF - Revista Argentina de Cardiologia
IS - 2
ER -